Summary
This project in the Czech Republic had two aspects as the title indicates.
The HCl filter served a negative air system which was created in a building to surround a soil remediation site.
The process of clearing this Hazardous Waste site involved various systems (specified by others) to protect the workers.
Unfortunately, these systems were not operating correctly and this lead to worker illness developing.
Filter Designs was used initially as a consultant and then as a supplier of the filter system and components.
The system was designed, manufactured and installed by Filter Designs.
Supply Highlights
We were contracted to provide 2 small Ceramic filters suitable for a small volume but with a design maximum temperature of 600°C. In addition the filters will be handling a syngas which cannot be mixed with oxygen so an alternative to compressed air would need to be used for the ‘Cleanpulse’ cleaning of the 25 Ceramic element in each of these CPC78 filters. In addition dosing of small amounts of a re-agent is required so the client also opted for a ‘Cleandose’ 25kg bag skid. Find out more about Project CAD below.